HomelinessTools and equipment

Beretta (gas boiler): instructions, reviews

Have you faced the problems of central heating or hot water supply for a long time? These issues can be solved by installing a gas boiler.

Problems with central heating

The solution can be a single-circuit or dual-circuit boiler. The first variety is capable of providing the heating process. With the help of a two-circuit device it is possible to provide not only heating of premises, but also heating of the coolant for solving household tasks. If you decide to purchase a two-circuit gas boiler Beretta, then it is worth remembering that its installation will be quite a troublesome and time-consuming process.

Feedback on the rules for installing a gas boiler

Many people like the products of the Beretta trademark. A gas boiler of this manufacturer can be purchased at an affordable cost. Before you begin to install the device in a private house, you will need to prepare some documentation, as well as carry out certain actions. Thus, you need a contract for the supply of gas for the developer, the installation project. Technical conditions must be agreed with the gas service representative.

Project documentation is most often developed by specialists of institutes that work under the appropriate license. Gas equipment should be installed by professionals from the installation organizations.

According to users, the engineer of the district organization should visit the facility in order to check whether the gas is correctly fed into the kitchen and into the furnace, whether the requirements are met. Quite often in recent years, consumers are choosing Beretta brand products, a gas boiler is also no exception.

After the expert is satisfied that all the norms are observed, he will give an opinion, on its basis it will be possible to open the valve, which leads to the equipment. The heating system must be pressed to P = 1.8 atm.

It will be important to de-dry the heating system. Experienced users emphasize that the connections must be checked for leaks, it is necessary to install a voltage regulator for the equipment and a source that will be responsible for uninterrupted power supply. It is worth remembering that in heating the coolant, in no case should antifreeze be added.

Feedback on the rules of boiler room design

When the Beretta wall-mounted gas boilers are purchased, they must be installed in rooms that are subject to certain requirements. When installing a boiler in a private one-family house, the boiler room or furnace room can be located on any floor, including on the basement, on the roof, in the attic or in the basement. The restriction applies only to living quarters, as well as to the bathroom and the bathroom, where the boiler is prohibited. Consumers emphasize that it is important to determine the volume of the boiler room, taking into account the thermal capacity of the equipment, the capacity of the water heaters, as well as the flow tanks.

For reference

If you decide to install a gas boiler "Beretta", then consider that when installing it is important to take into account some factors. So, if the device has a closed combustion chamber, then the boiler room volume is not normalized. In this case, not necessarily the presence of a window. For the removal and supply of oxygen, it is important to ensure the flow of air in the required volume.

Thus, if you installed a boiler with a capacity of 23.3 kilowatts, the gas will burn in a volume of 2.5 cubic meters per hour. In order to ensure complete combustion of this volume, you need 30 cubic meters of air per hour. If you do not guarantee sufficient air intake, then the gas will not burn completely, as a result, a harmful substance will begin to concentrate, its inhalation can negatively affect human health. If you inhale carbon monoxide within only 15 minutes, then death may occur. Oxygen must penetrate not only from the outside, but also from other premises of the house. This can be ensured by the presence of a gap that will be located between the door and the floor surface. It is also recommended to install a grate at the bottom of the door.

Advice of a specialist

Gas boiler Beretta should be installed on the floor with a deviation of ten centimeters from the wall, which should be made of non-combustible material. If there are no such surfaces, then you can install a special protection, which will be made of refractory material.

Installation Instructions

If these requirements are not met, the gas service will not allow the boiler to be connected to the central highway. However, the need to comply with these requirements is dictated not by bureaucracy, but by experience, as well as by fire safety. Restrictions apply not only to equipment and installation work, but also to the premises where the boiler is to be installed.

It must be remembered that the area of the boiler house should be equal to 4 meters square or larger, and ceilings - not less than 2.5 meters. When installing the door, please note that its width should be 80 cm or more. If you decide to prefer the manufacturer Beretta, the gas boiler of this company will meet all safety requirements, but it is important to follow the established rules. They assume the need for lighting equipment in a natural way through the window opening. On 10 square meters of one premise should be 0,3 square meters of a window aperture. It is very important to organize intensive ventilation, because the combustion of gas is provided by the principle of fresh air. To ensure the intake of outside air, it is necessary to provide a hole of 8 centimeters square per kilowatt of power of the device.

Additional Instructions

The gas boiler Beretta, whose comments are only positive, should be connected to the pipes of the gas pipeline, which are made exclusively of metal. The use of flexible hoses is permissible only for connecting individual consumers. The chimney must have a section that corresponds to the parameters of the unit's power. If it is equal to 30 kilowatts, then the diameter of the chimney should be 130 millimeters. With a power increase of up to 40 kilowatts, the diameter increases to 170 millimeters. In no way should the sectional area be smaller than the cross-sectional area of the opening for connecting this element.

If you decide to choose a gas boiler Beretta, the installation instructions for which are presented in the article, it is important to remember that the upper end of the chimney should be taken out 0.5 m above the ridge. This value is minimal.

What else should I pay attention to

Be sure to provide a gas analyzer, which should be located in the boiler room. With this device, you can prevent gas leakage. The device must be equipped with an electric valve. The latter is called upon to shut off the gas supply if necessary.

Manufacturer Beretta, whose gas boiler you can buy at specialized points of sale, indicates the possibility of placing the equipment in the basement of a single-family house. As for multi-storey buildings, installation of the device in the basement is prohibited.