The refrigerator is an important appliance in every home. Sometimes it happens that the equipment is out of order, because of what repairs are required. Faults can have a two-compartment refrigerator "Atlant". The refrigerating chamber does not work - this is a frequent phenomenon. In this case, the freezing chamber functions as usual. The reasons for this may be different.

Features of the refrigerator and freezers

To all worked without interruptions, you need to properly configure the refrigerator "Atlant", the instruction in this will help. The main part of the technology is the compressor, because it generates pressure, due to which the coolant moves towards the condenser. In this process, heat is generated, and you can verify this by touching the back of the device with your hand.

Then freon passes through the tubes and forms into the gas. To push the refrigerant you need power. Then freon enters the evaporator and starts to boil. An educated evaporator is considered cold.

It is in the freezer compartment that these tubes are located, and from here the cold enters the rest of the equipment. If there is no cold in the freezer, it will not be in the rest of the equipment. Then the coolant enters the compressor, so that the circulation turns. That is why the freezer has a low temperature in case of malfunctions.

What should I check?

It is necessary to properly configure the refrigerator "Atlant". The instruction includes important information on the operation of the equipment. To avoid damage to the device, it is necessary to pay attention to the following factors:

  • The doors of the refrigerator should be tightly closed, so you should remove everything that prevents it;
  • If the room is hot, then in the freezer you need to put the indicator of 2.5 (temperature about 16 degrees), and in the refrigerator - 2;
  • When the "full noufrost" mode is set, the freezer fan can freeze, causing the cold to not penetrate the refrigerator compartment.

First signs of malfunctions

If the malfunction has a two-compartment refrigerator "Atlant" (the refrigerator does not work), then this can happen for various reasons. Usually, the temperature in the freezer is lowered, and in the refrigerator compartment the atmosphere is approaching +20 degrees. Another factor of malfunctions is the non-stop operation of the compressor. If it does not turn off periodically, it overheats.

If the refrigerator "Atlant" does not freeze , and the first signs of malfunctions appear, it must first be thawed. After a day, the device can be turned on again. In some cases, it functions normally, and then specialist help will not be required. Otherwise, you need to call a master who will identify the problem and repair the refrigerator "Atlant". Two-chamber or single-chamber - it does not matter, any model can usually be repaired.

Capillary tube

This part is in the evaporator circuit. If foreign substances have penetrated inside, the freezer will function, and the refrigerator compartment will not. As a rule, chips or oil penetrate into the tube. As a result, Freon can not work, and therefore it does not reach the freezer. If the cause of the defect lies exactly in this, then it is necessary to urgently call the master, so that due to the load there is no breakage.

Some owners cope with the problem themselves by tapping the capillary tubes to dislodge debris. In some cases, it saves. But the master cleans the capillary system, changes the filter, vacuums evaporation systems and refills the refrigerator with freon.

temperature sensor

Many problems can have a two-chamber refrigerator "Atlant". The refrigerator is not working? This is often associated with the ingress of water and products onto the hull. Often the temperature defect is associated with factory marriage. And it manifests itself not immediately, but after a while.

If the cause of equipment failure in the sensor malfunction, then a new device is required. Repair should be carried out as quickly as possible, because the service life of the instrument is shortened due to the intensity of the compressor. The procedure for replacing the equipment will not take long.

Evaporative system and compressor

Faults can have different two-compartment refrigerator "Atlant". The refrigerator is not working? This can happen because of a leak. A similar situation is observed when cracks appeared in aluminum or copper pipes. Freon enters the tubes and leaves through the holes. Because of this, the cold does not form. As a result, the pressure in the compressor has a negative effect on the operation of the device as a whole. This causes wear or damage to the equipment. Cracks are formed in the old device.

Because of the failure of one of the compressors all the models of Atlant refrigerators are broken. Two-chamber devices have 2 compressors, and therefore one can fail. Defects lie in wear, marriage, installation of poor-quality equipment.

It is desirable for a specialist to trust the repair of equipment, since he still has more knowledge and experience in restoring the work of technology. First, a diagnosis is performed, which allows you to identify shortcomings, and then perform the elimination of defects. Many representatives of repair companies perform diagnostics and repair directly at home, which is very convenient. Professional repair guarantees long-term operation of the refrigerator, so do not neglect the services of skilled craftsmen.